{"passport":{"unfragile":{"@version":"1.0","version":"2026-05","artifact":{"id":"tool_viz-ai","slug":"viz-ai","name":"Viz.ai","type":"product","url":"https://viz.ai","page_url":"https://unfragile.ai/viz-ai","categories":["data-analysis"],"tags":["medical-imaging","stroke-detection","clinical","real-time"],"pricing":{"model":"paid","free":false,"starting_price":null},"status":"active","verified":false},"capabilities":[{"id":"tool_viz-ai__cap_0","uri":"capability://healthcare.acute.ischemic.stroke.detection.from.imaging","name":"acute-ischemic-stroke-detection-from-imaging","description":"Analyzes CT and MRI brain scans to automatically detect signs of acute ischemic stroke, including identifying vessel occlusions and tissue infarction patterns. Provides confidence scoring and anatomical localization to support rapid clinical decision-making.","intents":["I need to quickly identify if a patient is having a stroke so we can start treatment immediately","I want to confirm stroke presence before administering time-sensitive thrombolytics","I need to know the location and extent of stroke to plan intervention strategy"],"best_for":["stroke centers and comprehensive stroke programs","emergency departments with high acute stroke volume","interventional radiology teams"],"limitations":["Requires high-quality, standardized CT/MRI imaging protocols","May have reduced accuracy with motion artifacts or non-standard scan techniques","Cannot replace clinical judgment; requires physician confirmation"],"requires":["DICOM-compatible imaging equipment","EHR integration capability","Trained radiology and clinical staff for interpretation"],"input_types":["DICOM medical imaging files (CT, MRI brain scans)"],"output_types":["structured alert with confidence score","anatomical localization map","real-time notification to care team"],"categories":["healthcare","medical-imaging","clinical-decision-support"],"confidence":0.5,"matches":0,"success_rate":0},{"id":"tool_viz-ai__cap_1","uri":"capability://healthcare.pulmonary.embolism.detection.from.ct.angiography","name":"pulmonary-embolism-detection-from-ct-angiography","description":"Automatically analyzes CT pulmonary angiography (CTPA) scans to identify pulmonary emboli in pulmonary arteries. Flags location, size, and severity to enable rapid anticoagulation or intervention decisions.","intents":["I need to rule out or confirm PE quickly in a hemodynamically unstable patient","I want to identify the extent of clot burden to determine treatment intensity","I need to alert the team immediately if PE is detected to prevent patient deterioration"],"best_for":["emergency departments","intensive care units","pulmonary and critical care teams"],"limitations":["Dependent on adequate contrast bolus timing and image quality","May miss subsegmental PEs in some cases","Requires standardized CTPA acquisition protocols"],"requires":["CT angiography imaging capability","EHR integration for alert routing","Clinical staff trained in PE management"],"input_types":["DICOM CT pulmonary angiography scans"],"output_types":["PE detection alert with severity classification","anatomical location of emboli","real-time notification to on-call physicians"],"categories":["healthcare","medical-imaging","clinical-decision-support"],"confidence":0.5,"matches":0,"success_rate":0},{"id":"tool_viz-ai__cap_2","uri":"capability://healthcare.aortic.dissection.detection.from.ct.imaging","name":"aortic-dissection-detection-from-ct-imaging","description":"Detects aortic dissection on CT angiography by identifying intimal flaps, false lumens, and dissection extent. Provides rapid classification to guide emergency surgical or endovascular intervention decisions.","intents":["I need to confirm aortic dissection immediately to initiate emergency management","I want to classify dissection type (A vs B) to determine surgical vs medical management","I need to alert the surgical team urgently if dissection is detected"],"best_for":["trauma centers","cardiac surgery programs","emergency departments with vascular surgery capability"],"limitations":["Requires high-quality CTA with proper timing","May have difficulty with motion artifacts or suboptimal contrast","Cannot replace expert radiologist review for complex cases"],"requires":["CT angiography imaging equipment","EHR integration with surgical team alerts","Vascular surgery and cardiothoracic surgery availability"],"input_types":["DICOM CT angiography scans of thorax/abdomen"],"output_types":["dissection detection alert with type classification","extent and location mapping","urgent notification to surgical teams"],"categories":["healthcare","medical-imaging","clinical-decision-support"],"confidence":0.5,"matches":0,"success_rate":0},{"id":"tool_viz-ai__cap_3","uri":"capability://healthcare.real.time.alert.routing.to.specialists","name":"real-time-alert-routing-to-specialists","description":"Routes AI-detected abnormalities directly to on-call specialists and attending physicians through integrated EHR notifications, SMS alerts, and paging systems. Eliminates manual handoff delays and ensures critical findings reach decision-makers immediately.","intents":["I want the right specialist notified instantly when a critical finding is detected","I need to reduce time between imaging and physician awareness of urgent findings","I want to ensure no critical alerts are missed due to communication breakdowns"],"best_for":["large hospital systems with integrated EHR infrastructure","health networks with multiple departments and on-call rotations","organizations with high-volume acute imaging"],"limitations":["Requires robust EHR integration which may be complex in legacy systems","Dependent on hospital having standardized on-call schedules and contact information","Alert fatigue possible if false positive rate is high"],"requires":["EHR system with API access","SMS/paging infrastructure integration","Defined alert routing protocols and on-call schedules","IT support for system maintenance"],"input_types":["AI detection results with confidence scores","patient identifiers and imaging metadata"],"output_types":["EHR notifications","SMS alerts to physicians","pager notifications","audit logs of alert delivery"],"categories":["healthcare","workflow-automation","clinical-decision-support"],"confidence":0.5,"matches":0,"success_rate":0},{"id":"tool_viz-ai__cap_4","uri":"capability://healthcare.imaging.quality.assessment.and.protocol.validation","name":"imaging-quality-assessment-and-protocol-validation","description":"Evaluates the technical quality of submitted medical imaging scans and flags those that don't meet standardized acquisition protocols or quality thresholds. Provides feedback to imaging technicians to ensure consistent, analyzable images.","intents":["I want to ensure imaging scans meet quality standards before AI analysis","I need to identify when technicians need retraining on proper imaging protocols","I want to reduce non-diagnostic scans that require repeat imaging"],"best_for":["radiology departments","imaging centers with quality improvement programs","hospitals implementing standardized protocols"],"limitations":["Cannot improve already-acquired poor quality images","Requires clear protocol standards to be defined upfront","May require technician retraining which takes time and resources"],"requires":["Defined imaging acquisition protocols","Technician training program","Quality metrics and thresholds","Feedback mechanism to imaging staff"],"input_types":["DICOM imaging files","imaging protocol specifications"],"output_types":["quality assessment report","protocol compliance flags","feedback for technicians","quality metrics dashboard"],"categories":["healthcare","quality-assurance","medical-imaging"],"confidence":0.5,"matches":0,"success_rate":0},{"id":"tool_viz-ai__cap_5","uri":"capability://healthcare.clinical.outcome.tracking.and.door.to.treatment.measurement","name":"clinical-outcome-tracking-and-door-to-treatment-measurement","description":"Tracks key performance metrics including door-to-imaging time, imaging-to-alert time, and door-to-treatment time. Provides dashboards and reports demonstrating clinical impact and workflow efficiency improvements.","intents":["I want to measure how much faster we're treating patients since implementing this system","I need to demonstrate ROI and clinical outcomes to hospital leadership","I want to identify bottlenecks in our acute care workflow"],"best_for":["hospital quality and performance teams","clinical leadership evaluating system effectiveness","organizations seeking to optimize acute care pathways"],"limitations":["Requires accurate timestamp data from EHR and imaging systems","Cannot account for all variables affecting treatment times (staffing, bed availability)","Outcomes depend on institutional implementation quality"],"requires":["EHR data access with timestamps","Imaging system integration","Clinical outcome data (treatment type, timing)","Data analytics infrastructure"],"input_types":["EHR timestamps","imaging system logs","treatment records","patient outcome data"],"output_types":["performance dashboards","outcome reports","trend analysis","comparative metrics"],"categories":["healthcare","analytics","quality-measurement"],"confidence":0.5,"matches":0,"success_rate":0},{"id":"tool_viz-ai__cap_6","uri":"capability://healthcare.multi.condition.screening.across.imaging.studies","name":"multi-condition-screening-across-imaging-studies","description":"Simultaneously screens a single imaging study for multiple acute conditions (stroke, PE, aortic dissection) in one analysis pass. Enables comprehensive evaluation without requiring separate dedicated scans for each condition.","intents":["I want to check for multiple life-threatening conditions in one imaging study","I need to avoid missing incidental findings of other acute conditions","I want to maximize the diagnostic value of imaging already performed"],"best_for":["emergency departments with polytrauma patients","critical care units evaluating unstable patients","hospitals with high-acuity patient populations"],"limitations":["Imaging must include anatomical coverage for multiple conditions","Some conditions may require different imaging modalities for optimal detection","Increased computational load may impact processing speed"],"requires":["Multi-condition AI models","Adequate imaging coverage of relevant anatomy","Sufficient computational resources"],"input_types":["DICOM imaging studies (CT/MRI with appropriate coverage)"],"output_types":["multi-condition detection report","prioritized alert list","confidence scores for each condition"],"categories":["healthcare","medical-imaging","clinical-decision-support"],"confidence":0.5,"matches":0,"success_rate":0},{"id":"tool_viz-ai__cap_7","uri":"capability://healthcare.confidence.scoring.and.clinical.decision.support","name":"confidence-scoring-and-clinical-decision-support","description":"Provides confidence scores and supporting evidence for each AI detection, helping clinicians understand the certainty level and make informed decisions about next steps. Includes visual highlighting of detected abnormalities.","intents":["I want to know how confident the AI is in its detection","I need to understand the reasoning behind the alert to make clinical decisions","I want to see where on the image the abnormality was detected"],"best_for":["radiologists and clinicians making treatment decisions","physicians new to the system learning to interpret AI output","cases where clinical judgment differs from AI detection"],"limitations":["High confidence scores don't guarantee clinical accuracy","Visual highlighting may be difficult to interpret in complex cases","Clinicians must still apply clinical judgment and not over-rely on scores"],"requires":["Trained clinical staff to interpret confidence scores","Understanding of AI limitations and false positive/negative rates","Clinical context from patient history and presentation"],"input_types":["AI detection results with probability scores","imaging data for visualization"],"output_types":["confidence percentage","visual highlighting on imaging","supporting evidence summary","alternative diagnoses consideration"],"categories":["healthcare","clinical-decision-support","explainability"],"confidence":0.5,"matches":0,"success_rate":0},{"id":"tool_viz-ai__cap_8","uri":"capability://healthcare.ehr.integrated.case.documentation","name":"ehr-integrated-case-documentation","description":"Automatically documents AI findings and alerts in the patient's EHR, creating audit trails and integrating with clinical workflows. Reduces manual documentation burden and ensures findings are part of the official medical record.","intents":["I want AI findings automatically documented in the patient record","I need an audit trail showing when alerts were generated and acknowledged","I want to reduce manual documentation time for clinicians"],"best_for":["hospitals with integrated EHR systems","organizations focused on reducing clinician documentation burden","systems requiring comprehensive audit trails for compliance"],"limitations":["Requires robust EHR integration which may be complex","Documentation format must comply with hospital standards and regulations","Clinicians still need to review and acknowledge findings"],"requires":["EHR system with API access","Defined documentation templates and standards","IT infrastructure for secure data exchange","Compliance with HIPAA and medical record regulations"],"input_types":["AI detection results","patient identifiers","imaging metadata"],"output_types":["EHR documentation entries","audit logs","alert acknowledgment records","clinical note integration"],"categories":["healthcare","workflow-automation","documentation"],"confidence":0.5,"matches":0,"success_rate":0}],"trust":{"score":34,"verified":false,"data_access_risk":"low","permissions":["DICOM-compatible imaging equipment","EHR integration capability","Trained radiology and clinical staff for interpretation","CT angiography imaging capability","EHR integration for alert routing","Clinical staff trained in PE management","CT angiography imaging equipment","EHR integration with surgical team alerts","Vascular surgery and cardiothoracic surgery availability","EHR system with API access"],"failure_modes":["Requires high-quality, standardized CT/MRI imaging protocols","May have reduced accuracy with motion artifacts or non-standard scan techniques","Cannot replace clinical judgment; requires physician confirmation","Dependent on adequate contrast bolus timing and image quality","May miss subsegmental PEs in some cases","Requires standardized CTPA acquisition protocols","Requires high-quality CTA with proper timing","May have difficulty with motion artifacts or suboptimal contrast","Cannot replace expert radiologist review for complex cases","Requires robust EHR integration which may be complex in legacy systems","builder identity is not verified yet","no observed match outcomes yet"],"rank_breakdown":{"adoption":0.21666666666666667,"quality":0.55,"ecosystem":0.27,"match_graph":0.25,"freshness":0.75,"weights":{"adoption":0.25,"quality":0.25,"ecosystem":0.1,"match_graph":0.35,"freshness":0.05}},"observed_outcomes":{"matches":0,"success_rate":0,"avg_confidence":0,"top_intents":[],"last_matched_at":null},"maintenance":{"status":"active","updated_at":"2026-05-24T12:16:34.117Z","last_scraped_at":"2026-04-05T13:23:42.563Z","last_commit":null},"community":{"stars":null,"forks":null,"weekly_downloads":null,"model_downloads":null,"model_likes":null}},"distribution":{"claim_url":"https://unfragile.ai/submit?claim=viz-ai","compare_url":"https://unfragile.ai/compare?artifact=viz-ai"}},"signature":"0afUjH15blQP3nHdLpT5aMI2i7PEuMgTIRT93ff+c2hDKjAyrKAxNUi2jYI0n6EQfWf75AlmBX0DJs5GQpl3Dw==","signedAt":"2026-06-20T22:46:15.373Z","signedBy":"unfragile.ai","version":1},"_links":{"self":"https://unfragile.ai/api/v1/passport/viz-ai","artifact":"https://unfragile.ai/viz-ai","verify":"https://unfragile.ai/api/v1/verify?slug=viz-ai","publicKey":"https://unfragile.ai/api/v1/trust-passport-public-key","spec":"https://unfragile.ai/trust","schema":"https://unfragile.ai/schema.json","docs":"https://unfragile.ai/docs"}}